Olsmed Medical • Deeply Rooted in Healthcare, Empowering Life & Wellness
Contact Now
Contact Now

Syringe Pump

BYZ-810 Series Syringe Pumps

Certified medical devices  Direct supply  After-sales support

BYZ-810 Series Syringe Pumps

d7898c46-1172-4b4a-84c8-363506beb389.jpg


Product data

Technical specifications

Key specifications and configuration details for BYZ-810 Series Syringe Pumps

Product Name
BYZ-810 Single-Channel Intelligent Micro Syringe Pump
Model
BYZ-810 (single-channel); BYZ-810T is the dual-channel model of the same series
Syringe Sizes
10 ml, 20 ml, 30 ml, 50 ml
Flow Rate Range
0.1 - 1500 ml/h (in 0.1 ml/h increments)
Bolus
1500 ml/h (50 ml/60 ml syringe), 900 ml/h (30 ml), 480 ml/h (20 ml), 240 ml/h (10 ml)
Infusion Modes
Three intravenous dosing modes: simple fixed-rate mode, time-volume mode, and body weight dose mode
Time-Volume Mode Parameters
Fluid volume 0.1 - 999.9 ml (increments of 0.1 ml); Time 1 - 9999 min (increments of 1 min); Accumulated volume 0.1 - 9999.9 ml; Limit volume 0.1 - 9999.9 ml
Body Weight Dose Mode Parameters
Drug amount 0.1 - 999.9 mg; Fluid volume 0.1 - 999.9 ml; Dose 0.01 - 99.99 μg/kg/min or 0.01 - 99.99 mg/kg/h; Body weight 0.1 - 300 kg
KVO Function
The system automatically activates the KVO (keep vein open) function when injection is completed
Volume Limit Function
The required drug amount can be preset; when the limited-volume injection is completed, the machine stops automatically and activates the KVO function
Custom Syringe Calibration
Comprehensive syringe brand and specification calibration technology ensures the use of syringes of all brands together with injection accuracy
Injection Accuracy
Mechanical accuracy within ±2%, flow rate accuracy within ±3%
Dual CPU Safety Design
Dual CPU architecture; the system self-checks on startup (including alarm lights and alarm volume) for safe and stable operation
Display
LCD screen plus digital tube dual display with a clear interface
Occlusion Pressure
Adjustable in multiple levels for more precise pressure detection
Audible & Visual Alarms
Drug nearly empty, injection completed, set dose injection completed, injection occlusion, syringe detached, incorrect installation, rate setting error, AC power disconnected, low battery; all alarms have voice prompts
Plunger Drive Structure
Compatible with syringes of all domestic brands and specifications; supports single-hand aseptic operation; includes a syringe installation detection switch with synchronous photoelectric indication
Power Supply
Mains (AC) power, built-in rechargeable battery power, vehicle 12 V power
Power Input
100 - 240 VAC, 50/60 Hz, built-in 11.1 V rechargeable battery pack
Stackable Use
Multiple single-channel units can be stacked to save space effectively
FAQ

Frequently asked questions about BYZ-810 Series Syringe Pumps

Answers to common questions about product selection, use, and support.

What is the difference between the BYZ-810 single-channel and the BYZ-810T dual-channel, and how should I choose?
Both belong to the BYZ-810 series and share the same Medical Device Registration Certificate. The BYZ-810 is a single-channel model that drives one syringe at a time and can be stacked with additional units to expand channels; the BYZ-810T is a dual-channel model with 2 syringe channels integrated in the housing, which can run independently or simultaneously and can be freely split and combined into 2 - 8 channels. For single-department, single-drug infusion, the 810 is more economical; for scenarios requiring simultaneous infusion of two drugs or where bedside space is limited, the 810T saves more space.
What are the appropriate applications for the three infusion modes?
Simple fixed-rate mode: only the rate needs to be set and infusion starts with one key, suitable for routine constant-rate drug delivery. Time-volume mode: set the time and fluid volume and the system automatically calculates the rate and injects, suitable for quantified dosing by treatment course. Body weight dose mode: after setting the drug amount, body weight, fluid volume, and dose, the system automatically calculates the rate, suitable for departments that dose in μg/kg/min or mg/kg/h (such as ICU, anesthesia, and pediatrics).
Which syringe sizes are supported? Must dedicated syringes be purchased?
It supports 10 ml, 20 ml, 30 ml, and 50 ml syringes and provides comprehensive syringe brand and specification calibration technology, compatible with syringes of all brands. No dedicated consumables are required, so hospitals can continue using their existing qualified syringes and reduce long-term costs.
What is the injection accuracy? Can it meet clinical precision dosing requirements?
Mechanical accuracy within ±2% and flow rate accuracy within ±3%. The device controls the flow rate and total volume through uniform advancement of the plunger and is equipped with multi-level occlusion pressure detection. It is more stable than manual injection and suitable for clinical scenarios requiring long-term micro-volume, constant-rate drug delivery.
What are the KVO and volume limit functions for?
KVO (keep vein open) automatically maintains the line at a low rate after injection is completed, preventing blood reflux and line blockage. The volume limit function allows the required drug amount to be preset; when the set amount is reached, the machine stops automatically and switches to KVO. Together they reduce the need for manual supervision and prevent over-infusion and line blockage.
What about battery life and power supply? Will a power failure interrupt drug delivery?
It supports three power modes: mains (AC) power, built-in rechargeable battery, and vehicle 12 V power. The power specification is 100 - 240 VAC, 50 - 60 Hz, with a built-in 11.1 V rechargeable battery pack. When mains power is interrupted, it automatically switches to the built-in battery to continue injection, suitable for maintaining continuous drug delivery during transport and sudden power outages.
What alarms does it have? Will it be too noisy in the ward at night?
It provides voice, text, and audible-visual alarms covering drug nearly empty, injection completed, set dose completed, injection occlusion, syringe detached, incorrect installation, rate setting error, AC power disconnected, and low battery. The alarm volume is adjustable and can be set to a suitable level for the ward environment.
Can the single-channel model be stacked for multi-drug combination therapy?
Yes. The BYZ-810 single-channel model supports stacking of multiple units, effectively saving space, and a combination of several units enables multi-drug combination infusion, suitable for departments whose medication regimens require flexible expansion.
What is the practical significance of adjustable multi-level occlusion pressure?
Different drugs and IV sets tolerate occlusion pressure differently. Multi-level adjustment allows the device to adapt to different clinical scenarios while ensuring safe alarms, avoiding frequent false alarms that interrupt infusion, and triggering an alarm in time in case of genuine occlusion, making pressure detection more precise.
How are product certification and after-sales service guaranteed?
The BYZ-810 Medical Single-Channel Micro Syringe Pump is a Class II Medical Device with Medical Device Registration Certificate No. 湘械注准20192140076, supplied directly by Olsmed Medical. Registration certificates and qualification documents required for hospital tenders and procurement can be obtained from Olsmed Medical, which also provides full lifecycle service including installation training, repair and maintenance, and spare parts supply.

Compliance Notice

This product is a medical device certified under NMPA, CE, ISO13485. It shall only be used by professional medical personnel in accordance with user manual and local regulations. Not for self‑diagnosis or self‑treatment. All information is for product display only, not medical advice.

Related products

More“BYZ-810 Series Syringe Pumps”