Syringe Pump

Dual Channel Injection Pump HF-620A

Certified medical devices  Direct supply  After-sales support

Dual Channel Injection Pump HF-620A
Product data

Technical specifications

Key specifications and configuration details for Dual Channel Injection Pump HF-620A

Model
HF-620A (dual-channel)
Channels
Dual channel; the two channels can run independently or simultaneously
Infusion Modes
Five modes: constant rate, time/total volume, drug dose by body weight, micro and programmable
Syringe Size
5~60ml, automatic recognition
Flow Rate Range
0.10~1500 ml/h
Flow Rate Increment
0.01 ml/h
Time Setting
1 second ~ 99 hours 59 minutes 59 seconds
Parameter Adjustment During Infusion
Total volume and flow rate can be modified during infusion
Rapid Purge
Supported, for rapid removal of air from the line
KVO Function
Adjustable from 0.10~5.00 ml/h to keep the vein open (KVO)
Occlusion Pressure
Dedicated pressure sensor, 20~150 kPa, sensitivity adjustable in 8 levels, with dynamic pressure display
Automatic Pressure Release
Automatic pressure release function
Display & Input
Large display with 8-level adjustable brightness; physical numeric keypad (0~9) input
Syringe Management
More than 20 syringe brands built in; additional brands can be added, and after calibration all syringe brands are supported
Safety Design
Multi-CPU design for safer infusion; comprehensive infusion alarm design
Accuracy
Infusion error ≤ ±2%
Battery
2600mAh lithium battery, over 7 hours of simultaneous use of both channels
Electrical Safety Classification
Class I equipment, CF-type applied part, IPX4 ingress protection (IP) rating
History Records
Stores up to 10000 history records
Intended Use
For intravenous drug infusion
Weight
3.5 kg
Dimensions
295mm × 150mm × 224mm
FAQ

Frequently asked questions about Dual Channel Injection Pump HF-620A

Answers to common questions about product selection, use, and support.

What are the advantages of the dual-channel HF-620A over a single-channel model?
The HF-620A integrates 2 infusion channels in one device, and the two channels can run independently or simultaneously, allowing combined infusion of two drugs on a single device, saving bedside space and the number of devices purchased. It is suitable for departments such as the ICU, emergency department and operating room that need to infuse multiple drugs at the same time.
Can the two channels be set independently for different drugs and flow rates?
Yes. Each channel independently sets the flow rate, fluid volume, time or drug dose by body weight parameters without interfering with the other; the two channels can also be started simultaneously as clinically required for synchronized or staggered administration.
What scenarios do the five infusion modes suit?
Constant rate mode: routine administration at a constant rate; time/total volume mode: the rate is calculated automatically from the set time and total volume; drug dose by body weight mode: the dose is calculated according to body weight; micro mode: low-speed, low-dose maintenance; programmable mode: stepped variable-rate infusion according to a preset program. The neonatal mode is particularly suitable for the neonatology department.
What are the infusion error and the flow rate range?
The infusion error is ≤ ±2%, the flow rate range is 0.10~1500 ml/h with a flow rate increment of 0.01 ml/h, and the time setting range is 1 second ~ 99 hours 59 minutes 59 seconds; the total volume and flow rate can be modified during infusion.
Which syringe sizes and brands are supported?
It supports automatic recognition of 5~60ml syringes and has parameters for more than 20 syringe brands built in; additional brands can be added, and after calibration all syringe brands are supported. No dedicated consumables are required.
How long does the battery last when both channels are in use?
The built-in 2600mAh lithium battery provides over 7 hours of simultaneous use of both channels, meeting the need for continuous administration during intra-hospital transport and sudden power failures without interrupting treatment to change batteries.
What are the occlusion sensitivity and pressure release functions for?
Occlusion detection uses a dedicated pressure sensor with a range of 20~150 kPa and 8-level adjustable sensitivity, and the pressure value is displayed dynamically; the automatic pressure release function releases pressure automatically when line pressure is too high, reducing the effect of high pressure on the line and the patient and adapting to different drugs and line characteristics.
What information does the display show? Is operation complicated?
The device has a large display with 8-level adjustable brightness and uses a physical numeric keypad (0~9) for input, allowing accurate operation even while wearing gloves. Parameters and operating status are clearly shown on the interface; no touchscreen is needed, avoiding accidental touches.
What should be noted about the IPX4 rating and cleaning and disinfection?
IPX4 means the device is protected against splashing water from all directions; for daily cleaning, simply wipe the housing with a damp cloth moistened with a neutral detergent. Avoid direct spraying or immersion and strongly acidic or alkaline disinfectants, and take care to prevent liquid from entering the control panel and the gaps around the keys. Before cleaning, switch off the power and remove the syringe.
How are product certification and after-sales service guaranteed?
The Hepho Dual-Channel Syringe Pump HF-620A is a Class II Medical Device with Medical Device Registration Certificate No. 粤械注准20192141164, supplied directly from the manufacturer by Olsmed Medical. Registration certificates and qualification documents required for hospital tenders and procurement can be obtained from Olsmed Medical, which also provides full lifecycle service including installation training, repair and maintenance, and spare parts supply.

Compliance Notice

This product is a medical device certified under NMPA, CE, ISO13485. It shall only be used by professional medical personnel in accordance with user manual and local regulations. Not for self‑diagnosis or self‑treatment. All information is for product display only, not medical advice.